Rossmax Technologies

Since 1988, Rossmax is committed to strive for the best technologies in each business field. Providing value for the customer’s specific need, is the key driver in inventing patented solutions. Rossmax does not compromise in fulfilling the highest quality standards and proofing the results through outstanding clinical validations.

Monitoring

Hypertension

AM/PM Averaging Mode

7-14-21-28-Day-AM-PM-Averaging
The exclusive AM/PM averaging memory mode provides you with a variety of options for reviewing your measurement history, including AM/PM Averaging. It calculates and displays 7/14/21/28 days average for measurements taken in the morning (AM) and nighttime (PM). Blood pressures can provide important information about how your blood pressure changes throughout the day. The monitor stores 28 days of Morning and Nighttime Averages for each user.

Auscultatory & Automatic mode - Switchable

Automatic-and-Auscultatory-mode
In the auscultatory mode the cuff will be automatically inflated. During deflation the Korotkoff sound will be detected manually with the stethoscope and the marker. Systolic and Diastolic values will be displayed on the device which can be used for fully automatic measurements as well.

Bluetooth Transmission Technology

Bluetooth
Rossmax also provides the latest Bluetooth 4.0 technology to transmit the device data to smart phones. This technology allows to send the measurement data to smart phones with integrated Bluetooth feature.

Cuff Detection (CD)

Cuff Detection
Detects and indicates whether the cuff is wrapped around the arm properly.

Digital Korotkoff

Digital-Korotkoff-Technology
DK Technology is a combination of the traditional Oscillometric method and Korotkoff sound method. With a microphone built into the arm cuff, DK Technology actually listens like your doctor when taking a reading. Exclusive DK Technology delivers ultimate accuracy by using both pressure and sound. The monitor is supported with an advanced "dual-sensor" cuff system. It has been shown that a device using the auscultatoric method has the potential to match the gold standard method more closely than devices using oscillometric methods.

Digital Pressure Gauge (Mandaus II)

Markers-for-Systolic-and-Diastolic
Different from other gauge, the Rossmax Digital Gauge’s marker feature ensures the accuracy during the measurement. The Digital Gauge is able to record the Korotkoff sound for measuring systolic / diastolic pressure and then the blood pressure would be displayed on LCD, reducing misdiagnosis resulted from time difference. The digital operation and display design clearly indicates the pressure, heartbeat and deflation rate on the same LCD display. The backlight screen design is convenient for users that need lighting. And the large, clear LCD display is also more user-friendly and is shock and water resistant for professional use.

Digital Technology

Digital-Technology
Units equipped with Digital Technology uses the oscillometric method to detect your blood pressure. Manual inflation to the appropriate pressure, during the deflation, the device will detect the amplitude and slope of the pressure oscillations and thereby determine for you the systolic pressure, diastolic pressure, and pulse.

Hyptertension Risk Indicator


Hypertension-Risk-Indicator
The National High Blood Pressure Education Program Coordinating Committee (JNC-7) has developed a blood pressure standard, classifying blood pressure ranges into 4 stages. This unit is equipped with innovative blood pressure risk indicator, which visually indicates the assumed risk level (prehypertension / stage 1 hypertension / stage 2 hypertension) of the result after each measurement.

Irregular Heartbeat (IHB) Detector

Irregular-Heartbeat-Detector-IHB
The units equipped with Irregular Heartbeat (IHB) Detector allow those who have an irregular heartbeat to obtain accurate measurements alerting the user of the presence of an irregular heartbeat during the measurement. The Irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the irregular heartbeat symbol is shown frequently the doctor needs to be consulted.

Movement Detector

Movement-Detector
Body movement indication - The “Movement Detector” helps reminding the user to remain still and is indicating any body movement during measurement. The specified icon appears once a “body movement” has been detected during and after each measurement. Such detector helps remind the users to remain still during the measurement process and increases the accuracy of the measurement.

Mobile Calibration System

Mobile-Calibration-System
Most regulatory agencies suggest recalibration of a unit’s pressure readings, by due to the technical constraints; the unit can only be recalibrated by manufacturer or via sophisticated equipment. Knowing the importance of recalibration to the units and the users, Rossmax devoted 2 years to develop the world’s first mobile calibration system. Simply connect Rossmax unit to the system, with its intuitive operation, now the recalibration is only a matter of seconds.

PARR Technology

PARR Technology
Rossmax Blood Pressure Monitors with PARR TECHNOLOGY enables early detection to PREVENT STROKE AND OTHER CARDIAC DISEASES with only ONE single measurement.

Pulse Arrhythmia (PARR) technology specifically detects pulse arrhythmia, including Atrial Fibrillation (AF, AFib), Atrial and / or Ventricular Premature Contractions (PC), Tachycardia (TACH), and Bradycardia (BRAD). Pulse Arrhythmia may be related to cardiac disorders, needs medical attention and thus early diagnosis is of paramount importance. The PARR technology detects arrhythmia during regular blood pressure checks without any additional user skills, user interaction and measurement prolongation. Beside the blood pressure determination a specific pulse arrhythmia determination is provided with PARR. Learn more...

Rest Condition Detector

Rest-Condition-Detector
HEMODYNAMIC STABILITY DETERMINATION (HSD) - eliminates all possible blood pressure measurement error caused by mental and physical stress and avoids unnecessary multiple measurements to attain an average of your blood pressure. The lack of rest condition, which is detected by the HSD technique, is the most common error in the blood pressure diagnosis. The blood pressure results have to be obtained in sufficient rest condition in order to have an accurate medical judgement of a patient‘s blood pressure status.

Real Fuzzy

Real-Fuzzy-Technology
Real Fuzzy Technology determines ideal cuff pressure based on one‘s systolic blood pressure and arm size. Users no longer need to pre-set the inflation level before measurement. The technology eliminates arm discomfort through unnecessary high inflation settings and also prevents inaccurate readings caused by erroneous cuff inflation levels.

Smart Sense

Smart-Sense-Technology
Smart Sense Technology utilizes an advanced air control system. The electronic deflation valve delicately controls the deflation rate. It allows the monitor to detect and analyze pulse signals as well as adjusting cuff pressure during deflation. This significantly aids in making more precise analysis, improving accuracy silently and efficiently.

Talking Function

Talking-Funktion
Based on personal demand the talking function can be switched on or off. The unit offers a full talking guideance from start until the blood pressure is displayed.

Fever

Advanced Infrared measuring system

Temple-Temperature
For non-contact temperature measurement - The advanced infrared temperature measuring technology provides safe, accurate, reliable and hygienic readings for measuring both forehead and ambient temperature. The forehead temperature reading lookup table was calculated and developed based on systematic skin clinical data statistics to accommodate fever and non-fever subjects, under different operating environment. The one second measurement thermometer without contacting skin is a suitable choice for obtaining body temperature and prevents cross contamination by measuring around 5 cm from the forehead.

Contact Free Probe Cover Replacement Design

Contact-Free-Prove-Cover
Easy to replace a new ear probe cover before each measurement without touching the probe cover film to avoid cross-contamination.

Continuous Scanning Ear Mode

Continuous-Scanning-Mode
The continuous ear scanning mode views the entire ear canal and looks for the highest temperature that can be detected. Simply press and hold the start button for 3 seconds, gently rotate the probe inside the ear canal in a circular manner and the most accurate reading will appear.

Fast response

Fast Response
1~60 seconds quick measurement with flashing number display and Bi-Bi sound to remind you when measurement completes.

PLUG & SECURE Probe Cover

Plug-and-Secure-Probe-Cover
The patented “PLUG & SECURE” probe cover can offer an easy and accurate ear temperature measurement. Users can easily assure the probe cover is attached and the appliance is ready to use. The well-designed heat insulation probe can ensure accurate, consistent reading and short interval between each measurement. Clinical validation complies with ASTM 1965-98 and PrEN 12470-5.

Telephoto Temperature Measurement

Telephoto-Temperature-Measurement
For non-contact temperature measurement - Rossmax new gun type non-contact temple forehead thermometer provides a consistent and longer distance (within 10 cm) temperature measurement without skin contact.

Waterproof

Waterproof TG380
Water-proof probe, easy to clean the device and probe by using cotton swab with the Alcohol.

Pulse Oximeter

ACT - Artery Check Technology

Temple-Temperature
ACT (Artery Check Technology) processes SpO2 signals and determines the stiffness of the artery (Artery Condition) based on the derived wave form. It further classifies the arterial condition into 6 levels and presents the result in an intuitive graphical interface. Heart rate, SpO2 and artery condition are available at your fingertip! Artery condition tells the potential risk of the following diseases: Arteriosclerosis / Peripheral circulation disorder / Cardiovascular disease Monitoring your artery condition with Rossmax ACT-embedded Pulse Oximeter makes the early detection of these heart killers easier and faster.

3in1

3in1 Wireless Solution

3in1 Healthstyle

3in1-Healthstyle
Rossmax provides the most frequent used devices like Blood Pressure, Body fat analyzers and activity monitors with the latest Bluetooth 4.0 and NFC (Near Field Communication) technology for wireless connection. This technologies enables wireless transmission of the measuring data to smart phones or Personal computers. With the tailor-made APP “Healthstyle”, users can monitor and manage their health- and lifestyle much easier and comfortable.

NFC Transmission Technology

NFC-Technology
Rossmax provides the NFC (near field communication) technology in their blood pressure monitor, body fat analyzer and activity monitors. This technology allows to send the measurement data to smart phones with integrated NFC feature.

Bluetooth Transmission Technology

Bluetooth
Rossmax also provides the latest Bluetooth 4.0 technology to transmit the device data to smart phones. This technology allows to send the measurement data to smart phones with integrated Bluetooth feature.

-->